The radio controlled clock is connected to the COM2 port at the summator with
a COM1 / COM2 Y cable.
COM2 must be configured for use with the radio controlled clock.
Summator time is synchronized automatically as long as reception is good (always
at xhxx:05).
Deviations < 1 second are corrected once per hour. An accuracy level of ± 1
second is obtained.
Switching to and from daylight savings and standard time is initiated by an H
program (command: SUWI), because continuous reception is not assured, even with
the radio controlled clock.
Time synchronization of several summators is controlled by the summator with the
radio controlled clock.
|
Article Number |
| Radio controlled clock for U1600 |
DCF77-1600 |
| Radio controlled clock for U1601..3 |
DCF77-1601 |
|