Transducer for the conversion of frequency into a direct current or voltage
signal, which is proportional to the measured value
see also: SINEAX 
- Measurement input for sinusoidal, square-wave or distorted nominal input
voltage with dominant fundamental wave
- Input voltage: 10 to 690 V
- Measuring range limits 10 Hz to 1.5 kHz
- Auxiliary power: 85 to 230 V AC/DC
- Input frequency response time periods: 4
- Measurement output available with unipolar, bipolar or live-zero output
quantities
- Measuring method: digital period of oscillation measurement
- Power supply: integrated AC-DC power pack with large tolerance range for
universal use
- Standard GL (Germanischer Lloyd) / suitable for use on ocean-going vessels
- Housings:
SINEAX: P13/70 housing for top-hat rail mounting
EURAX: plug-in module (7 standard width units) for 19" rack
| Article No. |
Nom. Input Voltage |
Measuring Range |
Output |
| 534-2111110 |
10...230V |
45..55Hz |
0-20mA |
|
534-2112110 |
48..52Hz |
4-20mA |
|
534-2141110 |
45..55Hz |
0-20mA |
|
534-2442110 |
48..52Hz |
4-20mA |
| 534-2211110 |
230...690V |
45..55Hz |
0-20mA |
|
534-2212110 |
48..52Hz |
4-20mA |
| 534-2241110 |
45..55Hz |
0-20mA |
| 534-2242110 |
48..52Hz |
4-20mA |
Order other variants with complete order code (534-2... .) in accordance with
the data sheet. See data sheet for other measuring ranges, inputs, frequencies,