4¾ place, precision multimeter and temperature measuring instrument for energy technology, CAT II

- Display range: +/- 30,000 digits
- Inherent deviation: 0.05% of reading + 3 digits
- Measuring functions: 300.00 mV - 1000.0 V, 300.00 uA - 16 A, 300.00 Ohm - 30.000 MOhm,
3.000 nF - 30.000 mF, dBV, Hz, °C/°F,
- Stopwatch, 10 ms - 100 min.
- Expanded AAC function via additional current transformer with mA output
- MIN-MAX measurement value storage, DATA hold
- Continuity and diode testing
- Frequency and pulse generator, 1 Hz to 1 kHz
- Automatic range selection and battery cutoff
- Heavy-duty mA fuse with 1000 V nominal voltage
- Patented, automatic blocking system (ABS)
- IR data interface
- Integrated quartz movement
- Protective rubber cover
- CSA certification
- DKD calibration certificate
- CAT.II @ 600 V per IEC 61010-1
|